As the first company to introduce a general-purpose drive in Korea and the undisputed leader in the field of drives, LSIS developed iS7 drives, which provide advanced embedded functions and PLC (K120S), and recently released next generation products such as high voltage drives through continuous technology development. The company has had its products recognized as employing optimum solutions in Several industrial fields such as cranes, elevators, steel manufacturing, automobiles, air conditioning, and water treatment plants. Today, the company is expanding its market share both in Korea and overseas.
S100
Powerful sensorless control, and a diverse range of user friendly functions delivers added value to our customers.
Frame Design
Strong Performance
Powerful sensorless control Starting torque of 200%/0.5Hz is produced and provides robust power in the low speed region.
Selectable rotary/standstill aut-tuning Standstill auto-tuning is equipped to find motor constant without rotation under conditions where the system is installed or motor cannot rotate.
Flying start function Inverter capable fo quick reliable smooth restarts into bi-directional rotating loads.
Space efficient Design
Side by Side installation Minimized distance between products enables control panel size reduction when installing multiple AC Drive.
Smaller Size Main parts are optimally arranged inside through the use of thermal radiation analysis and 3-dimensional design to reduce the dimensions by up to 60%(volume based) compared to the previous product(iG5A)
Standard Compliance
Built-in DC reactor Effective in improving power factor and decreasing THD. ¡Ø 3-phase 400V 30~75kW
Built-in EMC filter Meets the electrical noise reduction regulation. Related standards : 2nd Environment / Category C3 (Class A) CE standard is certified ¡Ø C2 : 1-phase 200V 0.4~2.2kW ¡Ø C3 : 3-phase 400V 0.4~75kW
Global compliance (UL, CE) Global standard compliance ¡Ø UL, CE, Gost, C-tick and cUL
Dual rating operation It is designed to choose between heavy and normal duty operation.
Overload capacity ¡Ø Heavy duty operation : 150% of rated current, 60 seconds ¡Ø Normal duty operation : 120% of rated current, 60 seconds
Various field networks Able to deal with a variety of field networks Easy maintenance and mounting.
Various field bus options Profibus, Ethernet IP, Modbus TCP, CANopen Easy to install and use
Safety Function
Built-in Safety Torque Off(STO)
The Safety input function meets EN ISO 13849-1 PLd and EN 61508 SIL2 (En 60204-1, stop category 0). This feature is equipped and enables you to meet current safety standards.
Suitable for Users
Simple cooling fan replacement
Replaceable fan without complete disassembly.
Smart copier
1. Smart copier allows users to download & upload the parameters from/to S100 without AC input power.
2. Customized main firmware is able to be downloaded to S100 using Smart copier.
3. Firmware of main control and I/O saved in Smart copier can be downloaded to S100
Multi-keypad funcion
Single LCD keypad can be used to set up the parameters of a RS485 connected drives. LCD keypad (same as iS7 model) is used to easily set up the parameters. Parameters can be copied to other drives. Multi language support will be available.
Conduit option
S100 meets UL type 1 with this option.
Flange option
S100 allows its heatsink to be installed outside of panel for better cooling system with this option.
H100
HVAC Specialized AC Drive
Low Voltage VFD
H100
HVAC Specialized AC Drive
Frame Design
Maximized User Convenience
Communication Module
¡¤ RS-485 Capability is built-in ¡¤ Modbus-RTU, Metasys N2 ¡¤ BACnet MS/TP is embedded as standard ¡¤ LonWorks option can be added
Easy to Change Cooling Fan
It is easy to change a cooling fan without opening the cover of a drive
Keypad Exclusive for HVAC
Used to issue commands, configure drive parameters, and for monitoring drive status ¡¤ HAND mode(Local, Control, Mode) or AUTO Mode (Remote Control Mode) can be selected. - HAND Mode : Used when selecting frequency or run/stop commands. - AUTO Mode : Drive operated using the keypad. multifunctional terminal block and communic ¡¤ Fault Status Monitoring
Specification Level Option (Conduit Kit)
Acquired UL open type & enclosed type 1 certification ¡¤ When the conduit option is used, the drive meets UL Enclosed Type 1 specifications
Flange Type
If the space is too small, a heat sink can be installed outside the panel
DC Reactor
A built-in DC Reactor effective to improve power factor and reduce THD is installed. ¡¤ DC Reactor built-in as standard for 400V 37-90kW
Builit-in EMC Filter
A built-in EMC fiter to respond to the specifications for noise reduction ¡¤ 400V 0.75~30kW Built-in as default (C3) ¡¤ 400V 37~55kW Built-in option can be selected (C3) ¡Ø 75~90kW satisfies EMC specifications even without a filter.
Global Specifications Compliant
UL Plenum Rated (American standards for conditioner fire safety) ¡Ø suitable for installation in a Compartment Handing onditioned Air
Smart Copier ¡¤ Power-free Operation ¡¤ LED Feedback ; ¡¤ Parameters Read/Write ¡¤Easy to Install
Data Flow in Smart Copier
Efficient Use of Space
Side-by-Side Installation
The size of control board is significantly reduced when multiple drives are installed by minimizing distance between products installed. ¡ØSibe-by-side installation is unavailable for 37~90kW.
Reduced Size Main Components are optimally deployed through thermal radiation analysis and 3D design to reduce size by 34% compared to iP5A(Volume based).
Stable System Control
LSLV-H100 drives are intelligent drives equipped with various protective and operation functions for continuously stable operation in response to external environmental changes.
Soft Fill Operation Prevents pump damages caused by dramatic pressure changes during intial operation or pumps or inside pumps.
Start Ramp & End Ramp Prevents pump damage by changing ramp using acceleration / deceleration time setting upon initial pump operation and stop
Dec Valve Ramp Prevents pump and pipe damages caused by sudden pressure changes when pumps are stopped or a pump valve is closed, deceleration time can be set.
Multi Motor Control MMC is used when a single drive is used to control multiple motors in pump systems. It can control 1 main motor and 5 auxiliary motors.
Scheduling (Time Event: Real Time Clock) Prevents pump damages caused by dramatic pressure changes during intial operation or pumps or inside pumps.
Flow Compensation Compensates for hydraulic loss that occurs when the length of pipes is long, adding compensation rate depending on the inverter output frequency.
Energy-saving Display (Payback Counter) Commercial energy consumption is compared to the amount of enery used by the drive to calculate the amount of energy saved.
Power-on Resume When the drive restarts after it was stopped due to power interruption upon communication control, 'Power-on Resume' is used to follow the previous control command.
Sleep, Sleep Boost, Wake-up It is used to put the drive on standby and restarts it using amount of enery used by the drive to calculate the amount of energy saved.
Auto Torque Boost The drive outputs voltage for the drive by controlling the level of boost to fit the load by itself.
Lubrication Control When a control command is made in the Flow/Oiling Systems, lubrication signals are output for a certain period before the motors are started. Drive control is immediately started form the signal output point until the signals are turned off after the set time
Damper Control When a Damper exists in the system configuration, the drive will command the Damper to open/close or receive feedback signals for protection.
Detection of Pipe Broken Upon PID operation, pipe damages or leakage is detected to display a warning or a trip.
Level Detection When the drive is operated under frequency that is beyond the set frequency and source (voltage, current, and etc.) values to be detected are above or below the user set values, it generates a trip or activates a relay for protective operation
Pre-Heat Pre-heats motors by outputting direct current when the motors are at fixed time state in order to prevent condensation of the motors
Under Load Protection When running pumps including No Flow and Dry Pumps under the set frequency. the drive issues warning function and when trip is generates, Free-Run, deceleration, or stop can be selected via parameters.
Macro Setting If a particular application is selected, frequently used parameters and set values are changed and registered in a macro group
KEB, Kinetic Energy Buffering Upon loss or momentary interruption of input power, if KEB is set, the drive maintains DC Link Voltage using regeneration energy of the motor is used during the interruption period.
Pump Clean Upon pump operation, the efficiency of pumps may decline when foreign substances are stuck in an impeller. Pump Clean removes the foreign substances to extend the pump life and reduce any loss
Aux Motor PID Compensation Pipe flow increases and conduit pressure decreases as the number of auxiliary motors increases. To compensate this, 'Aux Motor PID Compensation' is used to compensate pressure loss suitable for the given motor when operating auxliary motors.
Load Tuning Establishes load (current & power) curves based on drive frequency so as to make load characteristics curve required for 'Under Load' and 'Pump Clean.'
Fire Mode When an emergency such as fire occurs at suction/ exhaust fans, but hardware did not fail nor had a critical defect, the drive is continuously operated to protect other systems under the set frequency and direction.
iG5A
Powerful & compact sensorless vector control VFD LS Starvert iG5A is very competitive in its price and its functional strength compared to iG5. User-friendly interface, extended inverter ranges up to 7.5kW, superb torque competence and small size of iG5A provides an optimized user environment.
Features
Selectable V/f, sensorless vector control
Motor parameter Auto-tuning
Powerful torque at overall speed range
0.1 ~ 400Hz frequency output
-15% ~ +10% input voltage margin
Fault history: Last 5 faults
0~10Vdc / -10 ~ +10Vdc analog input
IP20 enclosure, UL Type 1 (Option)
Selectable manual/automatic torque boost
Selectable PNP/NPN input signal
2nd motor control and parameter setting
Built-in Dynamic braking transistor as standard
Enhanced process PID control
Built-in RS485 (LS Bus / Modbus RTU) communication
Cooling fan On/Off control & Easy change
Remote control using external keypad * RJ45 cable(Optional)
Upgraded functions:
Sleep & Wake-up (Energy savings)
KEB(Kinetic Energy Buffering) protection
Low leakage PWM algorism
Monitoring & commissioning PC based software tool (Drive View)
iS7
High Torque Performance and Precise VFD Inverter featuring on strong torque performance and accurate control for general use iS7 generates more powerful performance in terms of V/F control, V/F PG, slip compensation, sensorless vector control, PMSM (Permanent Magnetic Synchronous Motor) and focuses on user-friendly interface and environment-friendly features including wide graphic LCD keypad, user & macro group support, electro-thermal functions for motor protection, protection for input/output phase Open.
Features
Powerful Performance
Control mode: V/F, V/F PG, Sensorless Vector, Vector
Speed Control Range 1:100(Sensorless Vector), 1:1000(Vector)
Max. Input 11 Points, Output 6 Points when use expended I/O Card
PLC Card option: Master-K platform Normal Input 14 Points, Normal Output 7 points
Encoder Card option
Optional IP54 Enclosure (~ 22kW)
Convenience & Environment
Built-in EMC filter to protect from excessive electronic distortion
DC reactor built-in for harmonic reduction and power factor improvement
Widened graphic LCD keypad
Multi-language support (5 languages)
User & macro group support
iP5A
Fan & Pump specialized VFD Starvert iP5A series adopt various functions as standard for operation of Fan and Pump.
Features
Dual PID
When additional PID control or Cascade PID control is required, Dual PID provides users various uses of the system with only iP5A.
Multi Motor Control
The built-in algebra control function enables an inverter to control many motors without a controller so that user can take advantage of energy-saving and cost-down.
Sleep and Wake-Up
The built-in energy saving function makes inverter stop automatically when the capacity is very low.
Pre Heater
The pre heater function is built-in to prevent motor damage and inverter break-down caused from humidity.
Flying Start
When the inverter drives many ventilators or when the fan in a big load system turns due to a natural convection, iP5A operates the motor by searching the motor speed automatically.
Auto energy saving
iP5A provides the auto energy saving function by the optimal flux control which minimizes an energy loss caused by a change of the load.
Improved Management from Instant Power-off and Power Dip Generation
During the power Dip or instant power-off, which is generated by lightening, ground fault and power-failure, loads still keep the mechanical energy and this energy flows back to inverter by regeneration. The power-failure guarantee time is extended by using this electrical character of inverter.
Constant and Stable Performancel (24 hours 365 days)
Regardless of outside alteration such as input voltage variation by load change or weather effect, iP5A can handle moter and load with best performance.
Safety Stop
When unexpected power-failure blocks power supply, inverter stops motor by using inertia energy of load that prevents unexpected second accident (Parameter setting is required).
iV5
High duty full flux vector control VFD LS Starvert iV5 series realizes the high precision vector control in entire operational area and its highly precise speed control guarantees superb control stability in the elevator controls.
Features
Auto tuning In the application which requires a high torque at low speed, the electrical parameters of motor should be properly set for an optimal operation. Auto tuning function of iV5 make users to set the motor variable accurately.
various communication interface iV5 provides various communication interface such as RS 485, DeviceNET, Profibus-DP and Modbus-RTU.
Extended function card (ENC_DIV,DIAO and ELIO) Option card for the encoder pulse division (ENC_DIV) supports the encoder with open collector output and can divide the encoder pulse up to 1/128. Digital input and Analog signal output card (DIAO) can receive the binary speed command from PLC or other upper level controller and has 4 channels of analog signal output. ELIO card enables the lift application software to be available for an optimized lift operation.
Type
iE5
User friendly micro size slim VFD Inverter featuring on strong torque performance and accurate control for general use iS7 generates more powerful performance in terms of V/F control, V/F PG, slip compensation, sensorless vector control, PMSM (Permanent Magnetic Synchronous Motor) and focuses on user-friendly interface and environment-friendly features including wide graphic LCD keypad, user & macro group support, electro-thermal functions for motor protection, protection for input/output phase Open.
Features
V/f control
Compact size: 68 x 128 x 85mm (2.7 x 5 x 3.3 inch)
0.1 ~ 200Hz frequency output
1 ~ 10kHz carrier frequency
Fault history: Last 3 faults
IP20 enclosure
RS485 (LS Bus / Modbus RTU) communication (Built-in option)
DC Injection braking
Selectable manual/ automatic torque boost
Selectable PNP/NPN input signal
PI control
Up-Down & 3-Wire operation
Automatic restart after instantaneous power failure
Built-in potentiometer
Monitoring & commissioning PC based software tool (Drive View)
Parameter copy unit
Specification
Wiring
Function
iC5
High torque micro VFD Inverter featuring on strong torque performance and accurate control for general use iS7 generates more powerful performance in terms of V/F control, V/F PG, slip compensation, sensorless vector control, PMSM (Permanent Magnetic Synchronous Motor) and focuses on user-friendly interface and environment-friendly features including wide graphic LCD keypad, user & macro group support, electro-thermal functions for motor protection, protection for input/output phase Open.
Features
Sensorless vector control The iC5 adopts sensorless vector control algorithm, and it improves not only the torque control characteristics, but the speed controlability in an uncertain condition caused by the load variation as well.
Auto Tuning The auto tuning algorithm in the iC5 sets the motor factors automatically that brings the traditional commissioning difficulties mainly in low speed by the load variation and the low torque generation to a settlement.
Highly efficient DSP chip The iC5 adopts highly efficient DSP(Digital Signal Processing) chip to improve processing speed, flexibility, stability and etc.
PNP, NPN Dual Control Signal The iC5 provides PNP and NPN signals for outside controllers. It works with 24Vdc regardless of the type of PLC or control signals.
Communication interface, Modbus-RTU The iC5 provides the most popular communication interface, ModBus-RTU for remote control by PLC or other devices.
PID Control PID process control is used in iC5 to make speed corrections quickly with a minimal amount of overshoot and oscillation for the control of flow, temperature, pressure and etc.