H100(AC Drive)

Low Voltage VFD

As the first company to introduce a general-purpose drive in Korea and the undisputed leader in the field of drives, LSIS developed iS7 drives, which provide advanced embedded functions and PLC (K120S), and recently released next generation products such as high voltage drives through continuous technology development.
The company has had its products recognized as employing optimum solutions in Several industrial fields such as cranes, elevators, steel manufacturing, automobiles, air conditioning, and water treatment plants. Today, the company is expanding its market share both in Korea and overseas.
 

 

H100

HVAC Specialized AC Drive
 
Frame Design

Maximized User Convenience

 

Communication Module

¡¤ RS-485 Capability is built-in
¡¤ Modbus-RTU, Metasys N2
¡¤ BACnet MS/TP is embedded as standard
¡¤ LonWorks option can be added

Easy to Change Cooling Fan

It is easy to change a cooling fan
without opening the cover of a drive


Keypad Exclusive for HVAC

Used to issue commands, configure drive parameters, and for monitoring drive status
¡¤ HAND mode(Local, Control, Mode) or AUTO Mode (Remote Control Mode) can be selected.
- HAND Mode : Used when selecting frequency or run/stop commands.
- AUTO Mode : Drive operated using the keypad. multifunctional terminal block and communic
¡¤ Fault Status Monitoring



Specification Level Option (Conduit Kit)

Acquired UL open type & enclosed type 1 certification
¡¤ When the conduit option is used, the drive meets UL Enclosed Type 1 specifications


Flange Type

If the space is too small, a heat sink can be installed outside the panel



DC Reactor

A built-in DC Reactor effective to improve power factor and reduce THD is installed.
¡¤ DC Reactor built-in as standard for 400V 37-90kW
 


Builit-in EMC Filter

A built-in EMC fiter to respond to the specifications for noise reduction
¡¤ 400V 0.75~30kW Built-in as default (C3)
¡¤ 400V 37~55kW Built-in option can be selected (C3)
¡Ø 75~90kW satisfies EMC specifications even without a filter.

 


Global Specifications Compliant

UL Plenum Rated
(American standards for conditioner fire safety)
¡Ø suitable for installation in a Compartment Handing onditioned Air


Smart Copier
¡¤ Power-free Operation
¡¤ LED Feedback
; ¡¤ Parameters Read/Write
¡¤Easy to Install




Data Flow in Smart Copier

 
Efficient Use of Space

Side-by-Side Installation

The size of control board is significantly reduced when multiple drives are installed
by minimizing distance between products installed.
¡ØSibe-by-side installation is unavailable for 37~90kW.
Reduced Size
Main Components are optimally deployed
through thermal radiation analysis and
3D design to reduce size by 34% compared to
iP5A(Volume based).

Stable System Control

LSLV-H100 drives are intelligent drives equipped with various protective and operation functions for continuously stable
operation in response to external environmental changes.


Soft Fill Operation
Prevents pump damages caused by dramatic pressure
changes during intial operation or pumps or inside
pumps.
Start Ramp & End Ramp
Prevents pump damage by changing ramp using
acceleration / deceleration time setting upon initial
pump operation and stop


Dec Valve Ramp
Prevents pump and pipe damages caused by sudden
pressure changes when pumps are stopped or a pump
valve is closed, deceleration time can be set.
 
Multi Motor Control
MMC is used when a single drive is used to control
multiple motors in pump systems.
It can control 1 main motor and 5 auxiliary motors.


Scheduling (Time Event: Real Time Clock)
Prevents pump damages caused by dramatic pressure
changes during intial operation or pumps or inside
pumps.
Flow Compensation
Compensates for hydraulic loss that occurs when the
length of pipes is long, adding compensation rate
depending on the inverter output frequency.



Energy-saving Display (Payback Counter)
Commercial energy consumption is compared to the
amount of enery used by the drive to calculate the
amount of energy saved.

Power-on Resume
When the drive restarts after it was stopped due to power
interruption upon communication control, 'Power-on
Resume' is used to follow the previous control command.

Sleep, Sleep Boost, Wake-up
It is used to put the drive on standby and restarts it
using amount of enery used by the drive to calculate
the amount of energy saved.

Auto Torque Boost
The drive outputs voltage for the drive by controlling
the level of boost to fit the load by itself.

Lubrication Control
When a control command is made in the Flow/Oiling
Systems, lubrication signals are output for a certain
period before the motors are started. Drive control is
immediately started form the signal output point until
the signals are turned off after the set time

Damper Control
When a Damper exists in the system configuration,
the drive will command the Damper to open/close or
receive feedback signals for protection.


 

Detection of Pipe Broken
Upon PID operation, pipe damages or leakage is
detected to display a warning or a trip.

 

Level Detection
When the drive is operated under frequency that is
beyond the set frequency and source (voltage, current,
and etc.) values to be detected are above or below the
user set values, it generates a trip or activates a
relay for protective operation

Pre-Heat
Pre-heats motors by outputting direct current when
the motors are at fixed time state in order to prevent
condensation of the motors

Under Load Protection
When running pumps including No Flow and Dry Pumps
under the set frequency. the drive issues warning
function and when trip is generates, Free-Run,
deceleration, or stop can be selected via parameters.

Macro Setting
If a particular application is selected, frequently used
parameters and set values are changed and registered
in a macro group

KEB, Kinetic Energy Buffering
Upon loss or momentary interruption of input power,
if KEB is set, the drive maintains DC Link Voltage using
regeneration energy of the motor is used during the
interruption period.
Pump Clean
Upon pump operation, the efficiency of pumps may
decline when foreign substances are stuck in an
impeller. Pump Clean removes the foreign substances
to extend the pump life and reduce any loss

 
Aux Motor PID Compensation
Pipe flow increases and conduit pressure decreases
as the number of auxiliary motors increases. To
compensate this, 'Aux Motor PID Compensation' is
used to compensate pressure loss suitable for the
given motor when operating auxliary motors.

Load Tuning
Establishes load (current & power) curves based on
drive frequency so as to make load characteristics
curve required for 'Under Load' and 'Pump Clean.'


 

Fire Mode
When an emergency such as fire occurs at suction/
exhaust fans, but hardware did not fail nor had a
critical defect, the drive is continuously operated to
protect other systems under the set frequency and
direction.
 
 
 
 
 
Refer to website : www.lsis.biz
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.

ADD : Room 2317, Sambo Techno Tower, 122, Jomaru-ro 385beon-gil, Bucheon-si, Gyeonggi-do, Republic of Korea (14556)
TEL : +82-32-244-2551  |  FAX : +82-32-325-2551(local)  |  President : David Jung, Bongkwun
  E-mail : unitech@daum.net
Copyright © UNITECH Co., Ltd. All right reserved